![Xgn15](/uploads/s/5d9f31919c624c55bfd91f78e70d16a8.webp)
Xgn15
Overview Product DescriptionThe main switch of XGN15-12 sulfur hexafluoride ring network cabinet is FLN36-12 and FLN48-1
Overview
The Specification
Company Profile
Our main products are including switchgear, ring main unit, transformer,substation, and Other Power Transmission & Transformer. Our product has passed ISO9001 and CE certificate.
We have a professional technical team which can provide you with full design solution and technical support.Workshop
Project CaseCertifications
Basic Info.
Model NO. | XGN15 |
Application Range | Power Plants |
OEM | Avaliable |
Rated Frequency | 50/60Hz |
Rated Voltage | 12/24kv |
Transport Package | Wooden |
Specification | 1400*2200*2600 |
Trademark | kunji |
Origin | Wenzhou, Zhejiang |
HS Code | 8537209000 |
Production Capacity | 100/Week |
Product Description
Product DescriptionThe main switch of XGN15-12 sulfur hexafluoride ring network cabinet is FLN36-12 and FLN48-12 SF6 load switch. it can also be equipped with VS1, VD4/ S, ISM vacuum circuit breaker or HD4/ 55 SF6 circuit breaker according to the needs of users. Load switches and circuit breakers can be operated manually or electrically, and distribution automation can be realized with electric operating mechanism, PT, CT, FTU and communication devices.Working environment
1. The ambient air temperature : -25°C ~ +40°C;2. Daily average temperature(Within 24h): ≤+35ºC3. Altitude : less than 2000m;4. Relative humidity: within 24h, daily average value ≤ 95% , daily average vapor pressure≤ 2.2KPa;monthly average value ≤ 90%, monthly average vapor pressure≤ 1.8KPa* Ambient air is not significantly polluted by dust, smoke, corrosive and / or flammable gas, vapor or salt contaminationThe Specification
ITEM | UNIT | XGN15-12(F)/630-20 | XGN15-12(F.R)/T125-31.5 |
Rated voltage | KV | 12 | 12 |
Rated current | A | 630 | 125 |
Rated frequency | Hz | 50 | 50 |
Rated frequence withstand voltage | KV | 42/48 | 42/48 |
Rated impulse withstand voltage | KV | 75/85 | 75/85 |
Rated mainly acnive load breaking current | A | 630 | |
Rated closed-loop distribution circuit current | A | 630 | |
Rated short-circuit making current(peak) | KA | 50 | 80 |
Rated peak withstand current | KA | 50 | 50 |
Rated short-time withstand current | KA | 20 | 20 |
Rated duration of short circuit load break switch | S | 4 | 4 |
Rated SF6 gas pressure(20ºC gauge) | MPa | 0.04 | 0.04 |
Loop resistance | μΩ | <=200 | <=400 |
Mechanical endurance load break switch/earthing switch | KA | 5000/3000 | 5000/3000 |
Rated short-circuit breaking current | KA | 20/50 | 31.5/50 |
Rated transfer current | A | 1750 | |
Degree of protection | IP4X | IP4X |
Our main products are including switchgear, ring main unit, transformer,substation, and Other Power Transmission & Transformer. Our product has passed ISO9001 and CE certificate.
We have a professional technical team which can provide you with full design solution and technical support.Workshop
Project CaseCertifications
Low :next